I. Purpose
Specification of electromagnetic circuit test standards.
Ii. Scope of application
1. CE induction cooker;
2. If there is no special standard for other induction stoves (OEM, new type), it is also tested according to this standard.
Iii. Test items
1. Full functional test inspection
Test instrument/tool: regulated power supply, capacity greater than 2KVA
Test method: At rated voltage, according to the attached standard test induction cooker basic function.
Criteria: The function must be correct.
2. Full power test inspection
Test instrument/tool: regulated power supply, capacity greater than 2KVA
Screwdriver: rubber handle with a head size of 2.5mm-3mm, head length of more than 15mm, with a straight head
Standard pot (with a diameter of 200mm at the bottom, Q235A, 0.8-1mm thick)
Test method: At the rated voltage, test and adjust the power (adjust to the rated power -10%). (Example: 1600W: should be adjusted
1450W-1600W), and then measure the second gear power should be ±10% of the nominal power
Criteria: No defective products.
3. Complete inspection of POTS and pans
Test instrument/tool: regulated power supply, capacity greater than 2KVA
The diameters are φ80mm and φ120mm respectively
Test method: Start the machine under rated voltage,φ80mm gage placed in the circuit board ceramic plate arbitrary position induction furnace cannot be added
Hot; The electromagnetic cooker can be heated when the φ120mm gage is placed at any position on the ceramic board of the circuit board.
Criteria: No defective products.
4. Random check of temperature test
Test instrument/tool: regulated power supply, capacity greater than 2KVA
Standard pot,25±5℃ environment
Test method: At the rated voltage, add 50% oil (oil surface height about 100mm) in the standard pot to do the following test:
1) Insulation temperature of each section
2) Measure the oil temperature under any fire (protection temperature 260℃)
Criteria: error allowed ±20℃.
5. Full inspection of low voltage test
Test instrument/tool: regulated power supply, capacity greater than 2KVA
Test method: Adjust the voltage to 165V, and test the basic function of the induction cooker according to the attached standard.
Criterion: can work normally at low voltage.
6. Full inspection of high voltage test
Test instrument/tool: regulated power supply, capacity greater than 2KVA
Test method: Adjust the voltage to 265V, and test the basic function of induction cooker according to the attached standard.
Criterion: It can work normally for more than 2 hours at high voltage.
7. The first batch of full inspection for aging test, and then random inspection according to adverse conditions
Test method: Boil water for 1 hour at the second gear and the highest gear respectively under rated mains voltage.
Criteria: induction cooker shall not have any bad and abnormal.
8. Full dip test
Test method: no electricity to induction cooker is longer than the other side for shaft to 30 ゜ free fell three times.
Determination criteria: The completion of the test induction cooker power detection shall not have any bad and abnormal.
9. Regular test and spot check
Test method: 1. Test the precision of timing shutdown time under rated voltage.
2.. Test the 2-hour automatic shutdown function (do not move the pan or change the Settings during the test)
3. No pot 1 minute automatic shutdown function
Determination criteria: timing accuracy ±3%.
10. Spot check of blocked fan
Test method: Working at the rated voltage maximum firepower, blocking the fan.
Determination criteria: induction cooker can stop working or shut down, but can not have the danger of burning.
10. Pan testing spot check
Test method: Working at the maximum firepower under rated mains voltage, put the pot end more than 100mm away from the furnace surface and then put it back 50 times.
Criteria: The induction cooker can stop working or shut down, but there can be no bad or abnormal after the test.
11. Power plug plug test spot check
Test method: Working under rated mains voltage, plug and unplug the power plug 50 times at a rate greater than 50 times/min.
Criteria: The induction cooker can stop working or shut down, but there can be no bad or abnormal after the test.
12. Single side pad test spot check
Test method: Working under rated mains voltage, one side of the pot is padded with 6-8mm maximum firepower to boil water for 1 hour.
Criteria: The induction cooker can stop working or shut down, but there can be no bad or abnormal after the test.
13. Dry fire test spot check
Test method: Working under rated mains voltage, dry burning with empty pot under maximum fire power.
Criteria: The induction cooker can stop working or shut down, but there can be no bad or abnormal after the test.
14. Boil 300g oil for sampling test
Test method: Working under rated mains voltage, heating with standard cooker and 300g cooking oil at maximum heat.
Criteria: The induction cooker can stop working or shut down, but there can be no bad or abnormal after the test.
15. Appearance inspection: Complete inspection according to Emmett general standard
16. Packaging inspection and other: Complete inspection according to Emmett general standard